Search by VIN, equipment make, model, type or unit name, or by the part number of any oil:
Oil for Doosan, Forklifts, diesel, D/GXD, D30S-3 Plus (Cummins B3.3)
Doosan Model (Forklifts, diesel, D/GXD) to find out what kind of oil is used for it
Doosan Forklifts, diesel, D/GXD D30S-3 Plus (Cummins B3.3)from 1998 to 2003 Engine oil, automatic transmission fluid, manual transmission oil, antifreeze, brake fluid, power steering fluid and other fluids.
Power:
Nodes and assemblies
Engine Cummins B3.3
For mixed fleet
RAVENOL Turbo plus SHPD SAE 15W-40 is SHPD-motor oil for the mixed automobile fleet.
Manufacturer Approved:
Cummins CES 20076, Cummins CES 20077, Cummins CES 20078, DTFR 15B110, Deutz DQC III-10, MTU Type 2, Renault RLD, Renault RLD-2, TEDOM 258-3, Volvo VDS-3
Compliance with the requirements:
Allison C-4, Caterpillar TO-2, Global DHD-1, John Deere JDQ-78 A, MAN M 3275-1, MB 228.3, MB 229.1, Mack EO-M, Mack EO-M Plus, Scania LDF-2, ZF TE-ML 07C
- Available packaging
- Full description
- Product parameters
Volume:
1 L
Vendor code:
1123115-001
1123115-001-01-999
Volume:
4 L
Vendor code:
1123115-004
Volume:
7 L
Vendor code:
1123115-007
1123115-007-01-999
Volume:
1000 L
Vendor code:
1123115-700
1123115-700-01-999
RAVENOL Turbo plus SHPD SAE 15W-40 can be used for diesel and petrol engines, also with turbochargers.
RAVENOL Turbo plus SHPD SAE 15W-40 has been especially developed for extended oil change intervals, according to manufacturer’s recommendations.
Application instructions
RAVENOL Turbo-Plus SHPD SAE 15W-40 is recommended by the engine manufacturers for extended oil change intervals as SAE 15W-40 multigrade engine oil in heavy duty commercial vehicle diesel engines.
RAVENOL Turbo-Plus SHPD SAE 15W-40 is the preferred use for extended oil life in turbo charged diesel engines according to manufacturer’s recommendations.
Characteristics
- Extremely high pressure absorption capacity
- Very high oxidation stability
- Excellent aging stability
- Excellent viscosity and temperature behaviour
- High security reserves even under limited lubrication circumstances
- Suitable for extended oil change intervals
- Suitable for heavy operating conditions
| Parameter | Unit | Value | Tests | |
|---|---|---|---|---|
| SAE | 15W-40 |
15W-40
|
||
| Type | Mineral |
Mineral
|
||
| API | CI-4, SL |
CI-4, SL
|
||
| ACEA | A3, B4, E7 |
A3, B4, E7
|
||
| JASO | DH-1 |
DH-1
|
||
| Manufacturer Approved | Cummins CES 20076, Cummins CES 20077, Cummins CES 20078, DTFR 15B110, Deutz DQC III-10, MTU Type 2, Renault RLD, Renault RLD-2, TEDOM 258-3, Volvo VDS-3 |
Cummins CES 20076, Cummins CES 20077, Cummins CES 20078, DTFR 15B110, Deutz DQC III-10, MTU Type 2, Renault RLD, Renault RLD-2, TEDOM 258-3, Volvo VDS-3
|
||
| Recomendations | Allison C-4, Caterpillar TO-2, Global DHD-1, John Deere JDQ-78 A, MAN M 3275-1, MB 228.3, MB 229.1, Mack EO-M, Mack EO-M Plus, Scania LDF-2, ZF TE-ML 07C |
Allison C-4, Caterpillar TO-2, Global DHD-1, John Deere JDQ-78 A, MAN M 3275-1, MB 228.3, MB 229.1, Mack EO-M, Mack EO-M Plus, Scania LDF-2, ZF TE-ML 07C
|
||
| Suitable for | IVECO, Steyr Motor GAZ 560, YaMZ |
IVECO, Steyr Motor GAZ 560, YaMZ
|
||
| Density at 20 °C | g/cm³ | 870 | EN ISO 12185 |
870
g/cm³
EN ISO 12185
|
| Color | tan | visual |
tan
visual
|
|
| Viscosity at 100 °C | mm²/s | 15 | DIN 51562-1 |
15
mm²/s
DIN 51562-1
|
| Viscosity at 40 °C | mm²/s | 115.7 | DIN 51562-1 |
115.7
mm²/s
DIN 51562-1
|
| Viscosity Index VI | 134 | DIN ISO 2909 |
134
DIN ISO 2909
|
|
| tbn | mgKOH/g | 10.5 | ASTM D2896 |
10.5
mgKOH/g
ASTM D2896
|
| Approvals | Allison C-4, Caterpillar TO-2, Cummins CES 20076, Cummins CES 20077, Cummins CES 20078, DTFR 15B110, Deutz DQC III-10, Global DHD-1, John Deere JDQ-78 A, MAN M 3275-1, MB 228.3, MB 229.1, MTU Type 2, Mack EO-M, Mack EO-M Plus, Renault RLD, Renault RLD-2, Scania LDF-2, TEDOM 258-3, Volvo VDS-3, ZF TE-ML 07C |
Allison C-4, Caterpillar TO-2, Cummins CES 20076, Cummins CES 20077, Cummins CES 20078, DTFR 15B110, Deutz DQC III-10, Global DHD-1, John Deere JDQ-78 A, MAN M 3275-1, MB 228.3, MB 229.1, MTU Type 2, Mack EO-M, Mack EO-M Plus, Renault RLD, Renault RLD-2, Scania LDF-2, TEDOM 258-3, Volvo VDS-3, ZF TE-ML 07C
|
||
| Recommendations | Allison C4, Caterpillar TO-2, Global DHD-1, IVECO, JASO DH-1, John Deere JDQ-78A, MAN M 3275-1 (Multigrades), MB 228.3, MB 229.1, Mack EO-M, Mack EO-M Plus, Scania LDF-2, ZF TE-ML 07C |
Allison C4, Caterpillar TO-2, Global DHD-1, IVECO, JASO DH-1, John Deere JDQ-78A, MAN M 3275-1 (Multigrades), MB 228.3, MB 229.1, Mack EO-M, Mack EO-M Plus, Scania LDF-2, ZF TE-ML 07C
|
Hydraulic system power steering
RAVENOL Hydraulikoel TS 32 (HLP)
For hydraulics
RAVENOL Hydraulikoel TS 32 (HLP) is optimal alloyed mineral hydraulic oil with a high performance level and a wide application area of the whole industry.
Compliance with the requirements:
AFNOR NFE 48-603 HM, Bosch Rexroth RE 90220, Cetop RP 91H HM, Danieli Hydraulics, Eaton Vickers I-286-S, FZG Test A 8,3/90, Fives Cincinnati P-38, Fives Cincinnati P-68, GB 111118.1 L-HM, GM LH-02-1-04, GM LS-2, ISO 11158 HM, JCMAS HK, MIL-PRF-17672 E, Müller , Parker Denison HF-0, Parker Denison HF-1, Parker Denison HF-2, SAE MS 1004 HM, SEB 181.222, Sauer-Danfoss 520L0463, U.S. Steel 126, U.S. Steel 127, U.S. Steel 136, VDMA 24318, Vickers M-2950-S, Vickers Pumpentest
SAE: 32W
- Available packaging
- Full description
- Product parameters
Volume:
1 L
Vendor code:
1323104-001
1323104-001-01-999
Code:
4014835759312
Volume:
5 L
Vendor code:
1323104-005
1323104-005-01-999
Code:
4014835759350
Volume:
20 L
Vendor code:
1323104-020
1323104-020-01-999
Code:
4014835759329
Volume:
20 L, ecobox
Vendor code:
1323104-B20
Volume:
60 L
Vendor code:
1323104-060
1323104-060-01-999
Code:
4014835759367
Volume:
208 L
Vendor code:
1323104-208
1323104-208-01-999
Code:
4014835759381
Volume:
1000 L
Vendor code:
1323104-700
RAVENOL Hydraulikoel TS 32 (HLP) with efficient additives offers an excellent corrosion protection even under extreme loads. The behaviour of sealing materials is neutral.
RAVENOL Hydraulikoel TS 32 (HLP) is characterised by good viscosity temperature behaviour, a high aging resistant and a solid corrosion protection.
Application instructions
RAVENOL Hydraulikoel TS 32 (HLP) is for universally use in all hydraulic systems.
RAVENOL Hydraulikoel TS 32 (HLP) is recommended in high performance hydraulic systems with high pressure pumps of all types, in sensitive control systems.
RAVENOL Hydraulikoel TS 32 (HLP) is used for hydraulic systems in agriculture, to supply small gearboxes and for use in circulating systems.
Characteristics
- a high performance level
- a very good viscosity temperature behaviour
- a high aging resistant
- an excellent corrosion protection
- a solid corrosion protection
- neutrality of sealing materials
| Parameter | Unit | Value | Tests | |
|---|---|---|---|---|
| SAE | 32W |
32W
|
||
| Type | Mineral |
Mineral
|
||
| ASTM | D6158 |
D6158
|
||
| Recomendations | AFNOR NFE 48-603 HM, Bosch Rexroth RE 90220, Cetop RP 91H HM, Danieli Hydraulics, Eaton Vickers I-286-S, FZG Test A 8,3/90, Fives Cincinnati P-38, Fives Cincinnati P-68, GB 111118.1 L-HM, GM LH-02-1-04, GM LS-2, ISO 11158 HM, JCMAS HK, MIL-PRF-17672 E, Müller , Parker Denison HF-0, Parker Denison HF-1, Parker Denison HF-2, SAE MS 1004 HM, SEB 181.222, Sauer-Danfoss 520L0463, U.S. Steel 126, U.S. Steel 127, U.S. Steel 136, VDMA 24318, Vickers M-2950-S, Vickers Pumpentest |
AFNOR NFE 48-603 HM, Bosch Rexroth RE 90220, Cetop RP 91H HM, Danieli Hydraulics, Eaton Vickers I-286-S, FZG Test A 8,3/90, Fives Cincinnati P-38, Fives Cincinnati P-68, GB 111118.1 L-HM, GM LH-02-1-04, GM LS-2, ISO 11158 HM, JCMAS HK, MIL-PRF-17672 E, Müller , Parker Denison HF-0, Parker Denison HF-1, Parker Denison HF-2, SAE MS 1004 HM, SEB 181.222, Sauer-Danfoss 520L0463, U.S. Steel 126, U.S. Steel 127, U.S. Steel 136, VDMA 24318, Vickers M-2950-S, Vickers Pumpentest
|
||
| specification | DIN 51524-2, ISO 6743-4 HM |
DIN 51524-2, ISO 6743-4 HM
|
||
| Suitable for | Atos, Metso |
Atos, Metso
|
||
| Density at 20 °C | g/cm³ | 848 | EN ISO 12185 |
848
g/cm³
EN ISO 12185
|
| Color | light yellow | visual |
light yellow
visual
|
|
| Viscosity at 100 °C | mm²/s | 5.8 | DIN 51562-1 |
5.8
mm²/s
DIN 51562-1
|
| Viscosity at 40 °C | mm²/s | 32.1 | DIN 51562-1 |
32.1
mm²/s
DIN 51562-1
|
| Viscosity Index VI | 123 | DIN ISO 2909 |
123
DIN ISO 2909
|
|
| Approvals | AFNOR NFE 48-603 HM, Bosch Rexroth RE 90220, Cetop RP 91H HM, DIN 51524-2, Danieli Hydraulics, Eaton Vickers I-286-S, FZG Test A 8,3/90, Fives Cincinnati P-38, Fives Cincinnati P-68, GB 111118.1 L-HM, GM LH-02-1-04, GM LS-2, ISO 11158 HM, ISO 6743-4 HM, JCMAS HK, MIL-PRF-17672 E, Müller , Parker Denison HF-0, Parker Denison HF-1, Parker Denison HF-2, SAE MS 1004 HM, SEB 181.222, Sauer-Danfoss 520L0463, U.S. Steel 126, U.S. Steel 127, U.S. Steel 136, VDMA 24318, Vickers M-2950-S, Vickers Pumpentest |
AFNOR NFE 48-603 HM, Bosch Rexroth RE 90220, Cetop RP 91H HM, DIN 51524-2, Danieli Hydraulics, Eaton Vickers I-286-S, FZG Test A 8,3/90, Fives Cincinnati P-38, Fives Cincinnati P-68, GB 111118.1 L-HM, GM LH-02-1-04, GM LS-2, ISO 11158 HM, ISO 6743-4 HM, JCMAS HK, MIL-PRF-17672 E, Müller , Parker Denison HF-0, Parker Denison HF-1, Parker Denison HF-2, SAE MS 1004 HM, SEB 181.222, Sauer-Danfoss 520L0463, U.S. Steel 126, U.S. Steel 127, U.S. Steel 136, VDMA 24318, Vickers M-2950-S, Vickers Pumpentest
|
||
| Recommendations | AFNOR NFE 48-603 HM, ASTM D6158, Atos, Bosch Rexroth RE 90220, CETOP RP 91H HM, Danieli Hydraulics, Eaton Vickers I-286-S, FZG-Test A 8,3/90, Fives Cincinnati P-38, Fives Cincinnati P-68, GB 111118.1 L-HM (conventional), GM LH-02-1-04, GM LS-2, ISO 11158 HM, JCMAS HK, M-2950-S, MIL-PRF-17672 E, Metso, Müller Weingarten, Parker Denison HF-0, Parker Denison HF-1, Parker Dension HF-2, SAE MS1004 HM, SEB 181.222, Sauer-Danfoss 520L0463, US Steel 126, US Steel 127, US Steel 136, VDMA 24318, Vickers-Pumpentest |
AFNOR NFE 48-603 HM, ASTM D6158, Atos, Bosch Rexroth RE 90220, CETOP RP 91H HM, Danieli Hydraulics, Eaton Vickers I-286-S, FZG-Test A 8,3/90, Fives Cincinnati P-38, Fives Cincinnati P-68, GB 111118.1 L-HM (conventional), GM LH-02-1-04, GM LS-2, ISO 11158 HM, JCMAS HK, M-2950-S, MIL-PRF-17672 E, Metso, Müller Weingarten, Parker Denison HF-0, Parker Denison HF-1, Parker Dension HF-2, SAE MS1004 HM, SEB 181.222, Sauer-Danfoss 520L0463, US Steel 126, US Steel 127, US Steel 136, VDMA 24318, Vickers-Pumpentest
|
Hydraulic oil
RAVENOL Hydraulikoel TS 46 (HLP) is optimal alloyed mineral hydraulic oil with a high performance level and a wide application area of the whole industry.
Compliance with the requirements:
AFNOR NFE 48-603 HM, Bosch Rexroth RE 90220, Cetop RP 2950-S, Cetop RP 91H HM, Danieli Hydraulics, Eaton Vickers I-286-S, FZG Test A 8,3/90, Fives Cincinnati P-55, Fives Cincinnati P-70, GB 111118.1 L-HM, GM LH-02-1-04, ISO 11158 HM, JCMAS HK, MIL-PRF-17672 E, Müller , NATO H-573, Parker Denison HF-0, Parker Denison HF-1, Parker Denison HF-2, SAE MS 1004 HM, SEB 181.222, Sauer-Danfoss 520L0463, U.S. Steel 126, U.S. Steel 127, U.S. Steel 136, VDMA 24318, Vickers Pumpentest, ZF TE-ML 07H
SAE: 46
- Available packaging
- Full description
- Product parameters
Volume:
1 L
Vendor code:
1323105-001
Volume:
10 L
Vendor code:
1323105-010
Volume:
20 L, ecobox
Vendor code:
1323105-B20
Volume:
208 L, print
Vendor code:
1323105-D28
RAVENOL Hydraulikoel TS 46 (HLP) with efficient additives offers an excellent corrosion protection even under extreme loads. The behaviour of sealing materials is neutral.
RAVENOL Hydraulikoel TS 46 (HLP) is characterised by good viscosity temperature behaviour, a high aging resistant and a solid corrosion protection.
Application instructions
RAVENOL Hydraulikoel TS 46 (HLP) is for universally use in all hydraulic systems.
RAVENOL Hydraulikoel TS 46 (HLP) is recommended in high performance hydraulic systems with high pressure pumps of all types, in sensitive control systems.
RAVENOL Hydraulikoel TS 46 (HLP) is used for hydraulic systems in agriculture, to supply small gearboxes and for use in circulating systems.
Characteristics
- a high performance level
- a very good viscosity temperature behaviour
- a high aging resistant
- an excellent corrosion protection
- neutrality of sealing materials
| Parameter | Unit | Value | Tests | |
|---|---|---|---|---|
| SAE | 46 |
46
|
||
| Type | Mineral |
Mineral
|
||
| ASTM | D6158 |
D6158
|
||
| Recomendations | AFNOR NFE 48-603 HM, Bosch Rexroth RE 90220, Cetop RP 2950-S, Cetop RP 91H HM, Danieli Hydraulics, Eaton Vickers I-286-S, FZG Test A 8,3/90, Fives Cincinnati P-55, Fives Cincinnati P-70, GB 111118.1 L-HM, GM LH-02-1-04, ISO 11158 HM, JCMAS HK, MIL-PRF-17672 E, Müller , NATO H-573, Parker Denison HF-0, Parker Denison HF-1, Parker Denison HF-2, SAE MS 1004 HM, SEB 181.222, Sauer-Danfoss 520L0463, U.S. Steel 126, U.S. Steel 127, U.S. Steel 136, VDMA 24318, Vickers Pumpentest, ZF TE-ML 07H |
AFNOR NFE 48-603 HM, Bosch Rexroth RE 90220, Cetop RP 2950-S, Cetop RP 91H HM, Danieli Hydraulics, Eaton Vickers I-286-S, FZG Test A 8,3/90, Fives Cincinnati P-55, Fives Cincinnati P-70, GB 111118.1 L-HM, GM LH-02-1-04, ISO 11158 HM, JCMAS HK, MIL-PRF-17672 E, Müller , NATO H-573, Parker Denison HF-0, Parker Denison HF-1, Parker Denison HF-2, SAE MS 1004 HM, SEB 181.222, Sauer-Danfoss 520L0463, U.S. Steel 126, U.S. Steel 127, U.S. Steel 136, VDMA 24318, Vickers Pumpentest, ZF TE-ML 07H
|
||
| specification | DIN 51524-2, ISO 6743-4 HM |
DIN 51524-2, ISO 6743-4 HM
|
||
| Suitable for | Arburg, Atos, Metso |
Arburg, Atos, Metso
|
||
| Density at 20 °C | g/cm³ | 857 | EN ISO 12185 |
857
g/cm³
EN ISO 12185
|
| Color | light yellow | visual |
light yellow
visual
|
|
| Viscosity at 100 °C | mm²/s | 7.2 | DIN 51562-1 |
7.2
mm²/s
DIN 51562-1
|
| Viscosity at 40 °C | mm²/s | 47 | DIN 51562-1 |
47
mm²/s
DIN 51562-1
|
| Viscosity Index VI | 113 | DIN ISO 2909 |
113
DIN ISO 2909
|
|
| Demulsification | 40ml/40ml/10min. | DIN 51757 |
40ml/40ml/10min.
DIN 51757
|
|
| Aging stability, TOST | % | 2000 | DIN 51587 |
2000
%
DIN 51587
|
| FZG-Test A/8.3/90 Damage loading step | %wt. | 12 | DIN 51354/2 |
12
%wt.
DIN 51354/2
|
| Approvals | AFNOR NFE 48-603 HM, Bosch Rexroth RE 90220, Cetop RP 2950-S, Cetop RP 91H HM, DIN 51524-2, Danieli Hydraulics, Eaton Vickers I-286-S, FZG Test A 8,3/90, Fives Cincinnati P-55, Fives Cincinnati P-70, GB 111118.1 L-HM, GM LH-02-1-04, ISO 11158 HM, ISO 6743-4 HM, JCMAS HK, MIL-PRF-17672 E, Müller , NATO H-573, Parker Denison HF-0, Parker Denison HF-1, Parker Denison HF-2, SAE MS 1004 HM, SEB 181.222, Sauer-Danfoss 520L0463, U.S. Steel 126, U.S. Steel 127, U.S. Steel 136, VDMA 24318, Vickers Pumpentest, ZF TE-ML 07H |
AFNOR NFE 48-603 HM, Bosch Rexroth RE 90220, Cetop RP 2950-S, Cetop RP 91H HM, DIN 51524-2, Danieli Hydraulics, Eaton Vickers I-286-S, FZG Test A 8,3/90, Fives Cincinnati P-55, Fives Cincinnati P-70, GB 111118.1 L-HM, GM LH-02-1-04, ISO 11158 HM, ISO 6743-4 HM, JCMAS HK, MIL-PRF-17672 E, Müller , NATO H-573, Parker Denison HF-0, Parker Denison HF-1, Parker Denison HF-2, SAE MS 1004 HM, SEB 181.222, Sauer-Danfoss 520L0463, U.S. Steel 126, U.S. Steel 127, U.S. Steel 136, VDMA 24318, Vickers Pumpentest, ZF TE-ML 07H
|
||
| Recommendations | AFNOR NFE 48-603 HM, ASTM D6158, Arburg, Atos, Bosch Rexroth RE 90220, CETOP RP 2950-S, CETOP RP 91H HM, Danieli Hydraulics, Eaton Vickers I-286-S, FZG-Test A 8,3/90, Fives Cincinnati P-55, Fives Cincinnati P-70, GB 111118.1 L-HM (conventional), GM LH-02-1-04, ISO 11158 HM, JCMAS HK, LS-2, MIL-PRF-17672 E, Metso, Müller Weingarten, NATO H-573, Parker Denison HF-0, Parker Denison HF-1, Parker Dension HF-2, SAE MS1004 HM, SEB 181.222, Sauer-Danfoss 520L0463, US Steel 126, US Steel 127, US Steel 136, VDMA 24318, Verwendung lt. Betriebsanleitung, Vickers-Pumpentest, ZF TE-ML 07H |
AFNOR NFE 48-603 HM, ASTM D6158, Arburg, Atos, Bosch Rexroth RE 90220, CETOP RP 2950-S, CETOP RP 91H HM, Danieli Hydraulics, Eaton Vickers I-286-S, FZG-Test A 8,3/90, Fives Cincinnati P-55, Fives Cincinnati P-70, GB 111118.1 L-HM (conventional), GM LH-02-1-04, ISO 11158 HM, JCMAS HK, LS-2, MIL-PRF-17672 E, Metso, Müller Weingarten, NATO H-573, Parker Denison HF-0, Parker Denison HF-1, Parker Dension HF-2, SAE MS1004 HM, SEB 181.222, Sauer-Danfoss 520L0463, US Steel 126, US Steel 127, US Steel 136, VDMA 24318, Verwendung lt. Betriebsanleitung, Vickers-Pumpentest, ZF TE-ML 07H
|